Microbial air pollution in the dental center of a private university
Keywords:
Air Pollution, Aerosols, Bacterial contamination, Dental officeAbstract
Objective: The aim of this study was to evaluate the air microbial contamination before and during dental procedures (for 4 months) in two dental rooms, in the Dental Center of a private university of Lima- Perú. Material and Method: The study was carried out using a passive air sampling; settle plate, to identify potential infectious microorganisms. The samples were collected in five moments during the period from August to November in the 2017 year, outcomes were expressed in CFU/plate/hour and the Index of Microbial Air contamination (IMA) level was established. Results: In decreasing order it was found: S. negative mannitol (15.9 ± 12.9); yeast fungi (10.3 ± 8.2); S. aureus (9.1 ± 5.9); mold type fungi (1.6 ± 3.1) and enterobacteria (1.2 ± 1.3). Both dental rooms showed regular contamination estimated starting of the average of mesophiles (42.2 ± 22.2). Conclusions: It is necessary to implement methods to reduce the microbial contamination of clinical environments to reduce the risk of crosscontamination.Downloads
References
Tulchinsky T. Salud ocupacional y medioambiental. The new public health (third ed.) 2014; 471-533.
Paipay L, Calderón V, Maurtua D, Cristóbal R. Evaluación de la contaminación microbiológica en los equipos radiográficos de una clínica dental privada. Rev estomatol Herediana 2014; 24(2):73- 81.
Cellini L, Di Campli E, Di Candia M, Chiavaroli G. Quantitative microbial monitoring in a dental office. Public Health.2001;115:301-305.
Barlean L, Iancu L, Minea ,Danila I, Baciu D. Airborne Microbial Contamination in Dental Practices in Iasi Romania. OHDMBSC 2010;9:16-20.
Bentley C, Burkhart N, Crawford J. Evaluating spatter and aerosol contamination during dental procedures. J. Am. Dent. Assoc.1994;125(5):579-84.
Bustamante M, Herrera J, Ferreira R, Riquelme D. Contaminación microbiana generada por aerosoles en ambiente odontológico. Int J Odontoestomat. 2014; 8(1):99-105.
Prashanth T, Mandlik CB. Evaluation of aerosol and water contamination and cross infection in dental clinics. Med J Armed Forces India. 2010;66:37-40.
Pasquarella C, Veronesi L, Castiglia P, Liguori G. Italian multicentre study on microbial environmental contamination in dental clinics: a pilot study. Sci Total Environ 2010; 408:4045-51.
Pascuarella C, Pitzurra O, Savino A. The index of microbial air contamination. J. Hosp. Infect. 2000;46:241-256.
Downloads
Published
Issue
Section
License
- Los autores/as conservarán sus derechos de autor y garantizarán a la revista el derecho de primera publicación de su obra, el cuál estará simultáneamente sujeto a la Licencia de reconocimiento de Creative Commons que permite a terceros compartir la obra siempre que se indique su autor y su primera publicación esta revista.
- Los autores/as podrán adoptar otros acuerdos de licencia no exclusiva de distribución de la versión de la obra publicada (p. ej.: depositarla en un archivo telemático institucional o publicarla en un volumen monográfico) siempre que se indique la publicación inicial en esta revista.
- Se permite y recomienda a los autores/as difundir su obra a través de Internet (p. ej.: en archivos telemáticos institucionales o en su página web) posterior al proceso de aprobación del manuscrito, lo cual puede producir intercambios interesantes y aumentar las citas de la obra publicada.